24kV VD4/R Indoor Lateral Vacuum Circuit Breaker (VCB)

Min. Order: 1 Set/Sets
Payment Terms: L/C, T/T, WU
Supply Ability: 1000 per month
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Distributor/Wholesaler

Product Detail

Model No.: VPE/R-24/1250-25
Means of Transport: Ocean, Air, Land
Type: Vacuum
Poles Number: 3
Brand Name: PURANA
Rated Voltage: 24kV
Rated Current: 1250A
Rated Short Circuit Breaking Current: 25kA
Rated Peak Withstand Current: 63
Production Capacity: 1000 per month
Packing: In wooden cases
Delivery Date: 20 working days ,or depending on ordering qty
Show

Product Description

VPE/R-24 indoor medium-voltage AC vacuum circuit breaker is a newest product designed by our company which is applicable to 3-phases AC50Hz, 24kV indoor switch systems. The product is with characteristics of smaller volume, reliable insulation, no pollution, long time free maintenance and so on. It is produced with standardized circuit breaker assembly line and has good performance and perfect quality.

Characteristics:
1. Equipped with modularized operating mechanism which make the maintenance and the replacing are more convenient. The replace of module do not affect the dynamic capability and also shorten the power-off duration.
2. The interrupter and primary circuit are sealed in the epoxy resin, which make the circuit breaker is more reliable.
3. The pole using converted and ventilated technique and lower resistance vacuum circuit breaker limit the temperature rising because of circuit breaker working for a long time and also reduce the power loss.
4. The operating mechanism is designed uniquely and avoid the moving contact over-rebounding when the circuit breaker is opened and prolong the vacuum interrupter mechanical life.
5. Past the type test according to the national standards, such as GB, DL, international standards of IEC, CEI, DIN, VDE and other major industrialized countries.

Main Technical Parameters of 24kV Vacuum Circuit Breakers:

Rated VoltageUr[kV]24
1min power frequency withstand voltage(effective value)Ud(1min)[kV]65
Lightning impulse withstand voltage(peak value)Up[kV]125
1min power frequency voltage of the secondary controlling circuit[V]2000
Power supply of controlling circuit[V]AC220/110, DC220/110
Rated frequencyFr[Hz]50/60
Rated operating sequence
O-0.3s-CO-180s-CO
Rated currentIr[A]1250
Rated short-circuit breaking currentIcs[kA]25
Rated short-circuit making currentIu[kA]50
Rated short-time withstand currentIk[kA]25
Rated peaking withstand currentIp[kA]50

Mechanical characters:

Mechanical lifetimeCycle20000
Electrical lifetime
E2
Contact Clearance[mm]14±1
Contact Overtravel[mm]3.5±1
Opening time[ms]20~50
Arcing time[ms]10~15
Full breaking time[ms]30~65
Closing time[ms]35~70

Frame of lateral vacuum circuit breakers:

Some production scenes:

Lateral vacuum circuit breaker running on test: