Maternal Fetal Monitor

Company Profile

Location: China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: RSD6002

Product Description

.12.1 inch super resolution color TFT display

2. Maximum 9 waveforms
3. Use built-in system, high integrated intelligent module technology, full digital monitoring, super functions, lowest * swearing and low failure rate
4. Combined functions of maternal monitor and fetal monitor
5. Measure the intrapartum patient and fetal heart rate
6. Uterine contraction and fetal movement marker
7. Continuous real time recording of fetal heart rate
8. Can be switched to normal patient monitoring interface
9. 72 hours graphic trends and tabular of all parameters
10.1440 groups of NIBP data storage
11. ST segment
12. Anti-high frequency electronic surgical unit and anti-defibrillation, for monitoring in the surgery or for cardiac care
13.Use wide-angle, multi-wafer, wide beam and ultrasonic probes
Technical Specifications:
Safety
IEC60601 approved (GB9706)
Power source
AC100V-240V, 50/60Hz
Size
330mm(L) ?275mm(W) ?160mm(H)
Net weight
5.0 kg
Working
Temperature: 5 ~ 40?
Humidity <= 85%
Transportation and Storage
Temperature: -20 ~ 55?
Humidity <= 85%
Ultrasonic Probe: (Fetal Heart Rate)
Type
Type B proof, dirctional, using pulse doppler system
Working frequency
2.5 MHz
Transmitting power density
1.2m W/cm2
Probe
Multi-wafer probe
Sample rate
5 ms
Calculating precision of FHR
0.25 bpm
Accuracy of FHR
1 bpm (100-180 bpm)
Marker (Fetal Movement)
Manually push button mode
When pressed, a red strip will be displayed above the FHR graph
Uterine Contraction Pressure
Type B proof
Uterine contraction pressure probe
Manual zero adjustment
Design pressure sensitivity: 0-100%
ECG
Lead
5 leads (R, L, F, N, C)
Lead selection
I, II, III, avR, avL, avF, V
Waveform
7 channels
Gain selection
?. 5, ?, ?
HR and alarm range
Adult: 15-300bpm
Neonate/pediatrics: 15-350bpm
Accuracy
?% or ?bpm, whichever is greater
Input impedance
> 5?O
Voltage range of electrode polarization
?00mV
Leakage current
< 30uA
Filter
Diagnostic mode: 0.05 ~ 100Hz
Monitoring mode: 0.5 ~ 35Hz
Surgical mode: 1 ~ 25Hz
Scaling signal
1mV ?3%
Measurement range
-1.0mV ~ +1.0mV
Alarm Range
-0.80mV~0.80mV
 RESP
Model
RA-LL impedance
Measurement range
Adult: 0 ~ 120bpm
Neonate/pediatrics: 1 ~ 150bpm
Resolution
1rpm
Accuracy
?rpm
NIBP
Method
Automatic oscillometric
Operation mode
Auto/Manual
Alarm Type
Systolic, Diastolic, Mean
Measurement ranges
Systolic BP: 40 ~ 300mmHg
Diastolic BP: 10 ~ 220mmHg
Mean BP: 20 ~ 240mmHg
Resolution
1mmHg
Accuracy
Max average error ?mmHg or ?%, whichever is greater
Overload Protection
Double safety protection
 SPO2
Measurement Range
0 ~ 100%
Alarm range
0 ~ 100%
Resolution
1%
Accuracy
?% (80~100%)
?% (60~79%)
 PULSE RATE
Range
0 ~ 254bpm
Resolution
1bpm
Accuracy
?bpm or ?%, whichever is greater
Alarm delay time
10sec
 TEMP
Channel
2 channels
Measurement range
0~50?
Alarm range
0~45?
Resolution
0.1?
Accuracy
?.2?
Standard configuration: 
FHR, Uterine Contraction Pressure(TOCO), FM and Maternal ECG, NIBP, SPO2, TEMP, RESP, PULSE, Built-in rechargeable battery, thermal printer