ECG
CMRR: >/=90dB
HR Measure and Alarm Range: 15-300bpm
Accuracy: +/-1bpm
Heart Rate Average: 8 beats
ST Segment Range: -0.8 to +0.8mV
Pacemaker suppression on PR: Amp: +/-2mV to +/-9mV
Range: 0.2ms to 2.0ms
Connector: AAMI 6-1 pi
Lead Selection: I, II, III, V, aVR, aVL, aVF
Lead Off Alarm: Visual and audible
Input: 5-lead ECG cable
QRS Indicator: Visual and audible
Sweep Speed: 12.5 /25 /50mm/s
Amplitude Selection: x1/4, x1/2, x1, x2, x4
Trend: 2 hours ,-4 hours ,-8 hours, -24 hours and -48 hours
Frequency Response:
Monitoring: 0.5 to 35Hz (+0.4dB, 3.0dB)
Surgical: 0.5 to 25 Hz (+0.4dB, 3.0dB)
Heart Rate Alarm Time: Less than 7 seconds
Aspect Ratio: 0.24~0.6sec/mv
Defibrillation Protection: 5kV test
Recovery Time after Defibrillation: Less than 5 seconds.
RESP
Measurement Mode: Thoracic Impedance
Respiration Rate and Alarm Range: 0-150brpm +/-2brpm
Waveform Display Speed: 6.25, 12.5 and 25mm/s
Refresh time: Approx. 2 seconds
TEMP
Measurement and Alarm Limit: 0-50 degrees
Probe: Skin surface or rectal /esophageal)
Unit: Celsius/Fahrenheit
Accuracy: +/-0.1 degrees
Resolution: 0.1 degrees
Refresh time: Approx. 4 minutes
NIBP
Measurement Method: Oscillometric
Parameters: Systolic, Diastolic, Mean, Pulse
Unit: mmHg or kPa
Operation Mode: Auto, Manual, STAT
Measurement and Alarm Range:
Systolic Pressure:
Adult/pediatric: 30-254mmHg (4.0-33.9kPa)
Neonate: 30-135mmHg (4.0-18.0kPa)
Diastolic Pressure:
Adult/pediatric: 10-220mmHg (1.3-29.3 kPa)
Neonate: 10-110mmHg (1.3-14.7kPa)
Cuff Pressure Range:
0-280mmHg (0-37.3kPa)
Initial Cuff Inflation Pressure:
Adult/Pediatric: 170+/-10mmHg (22.7 +/-1.3kPa)
Neonate: 90+/-10mmHg (16.0+/-1.3kPa)
Deflation Pressure: 30mmHg (4.0kPa) higher than last systolic pressure.
Cuff Inflation Speed: Not greater than 50mmHg /sec
Measurement Time:
It can not be chosen in Manual/Stat mode.
1s, 10s, 15, 30s, 60s, 90s, 120s, 180, 240s, 480s can be selected in
Auto mode.
Measurement Display Accuracy: +/-3mmHg
BP pulse Accuracy:
40~200bpm: +/-3bpm
200~240bpm: +/-5bpm
Cuff: Neonate, infant, small child, child, small adult, adult
SpO2
Measurement and Alarm Range: 0-100% Adult/Pediatric/Neonate
SpO2 Average: 8 beat average
Accuracy: +/-2% (90-100%), +/-3% (50-89%)
SpO2 Pulse Rate Range: 30-250bpm
SpO2 Pulse Rate Average: 8 seconds
SpO2 Pulse Rate Accuracy: +/-2% (30-100bpm)
Refresh Time: Approx. 2 seconds
Pulse Rate Alarm Limit: 0-250bpm
Pulse Sound: Pulse sound indication
Sensor Type: Finger clip, universal Y, silicone soft
Internal LED waveform: infrared=22.5Mv; Red light=30mV
Pulse Rate Display: Digit
Environment