user login

Processor of fresh air

5000.0 RMB
Min. Order: 5 Pair
Payment Terms: Pay a deposit after the first shipment
Supply Ability: 20000
Place of Origin: Henan

Company Profile

Location: Zhengzhou, Henan, China (Mainland)
Business Type: Manufacturer, Trading Company, Service
Main Products: Electronic Thermostat, Air Conditioning Module Machine, XPS Composite Duct, Water Source Heat Pump Unit, Plate Heat Exchangers

Product Detail

Means of Transport: Automotive
Production Capacity: 20000
Packing: Carton
Delivery Date: 15days
Show

Product Description

Currently, the vast majority of office buildings, office buildings, hotels, hotels, hospitals and other centralized cooling will use central air conditioning (heating), and generally is the use of fan coil plus fresh air system.
Since relatively large indoor and outdoor temperature difference, if only to reduce the indoor temperature by fan coil units (including the outdoor air temperature), willing to take a long time (some difficult to achieve.) Therefore, in general, there will be each floor will have a processor of fresh air, fresh air of the room taken pretreatment, so that you can ensure that the room temperature in a very short period of time required to reach the temperature setting.
If there is no automatic control system in the case, the summer temperature may drop too low (too high in winter liter) caused by energy waste; room that no one in particular in the case of more serious waste of energy. In addition, the temperature of cold and heat will make people feel uncomfortable, can not guarantee a comfortable environment.
Interested friends can calculate, reduce the indoor temperature in summer 2 ℃, more than a waste of energy?
The role of the various parts:
          The fresh air section: the fresh air section mainly to receive outdoor air, precipitation of impurities in the fresh air; new installation of air valve actuator valve (switch), and fan interlock. Recommended the installation of shade in the outdoor temperature sensor for return air temperature compensation.
         Filter section: filter is usually the beginning of a new wind effect (or called coarse) filter, mainly larger filter impurities; return air filter after paragraph filters are generally in effect, the general filter smaller impurities; if Asia will have clean air conditioning is efficient and effective filter section. All filters should be installed around the pressure switch for detecting the cleanliness of the filter, if the blocking impurities, will issue a warning signal.
        Cold section of the table: Table for two, if the cold section of the control, the winter and summer shares. Surface cooler intake temperature control valve installed (links), by adjusting the temperature control medium flow rate to achieve the purpose. When the air reaches the set temperature and humidity requirements, temperature control valve turn it on or off, the excess return chilled water through a third pathway to prevent the control valve in the shut off valve is small or large pressure difference before and after the pipe caused by other or hold back a bad water pump, and the impact of valve life. In addition, cooling the surface of the frost switch installed to protect the air conditioning, and fans, air valve chain.
         Humidification section: the role of humidification to prevent winter drying section or special requirements humidification humidification, humidification mode is generally wet or steam humidification membrane humidification.
 
 

Post Buying Request