user login

Power distribution cabinet

1000.0~12000.0 USD
Min. Order: 1 Set/Sets
Payment Terms: L/C, T/T
Place of Origin: Guangdong

Company Profile

Location: China (Mainland)

Product Detail

Model No.: RL-H
Means of Transport: All types
Application: Networking
Phase: Three Phase
Type: On-line
Protection: Overcurrent
Brand Name: Resden
Weight: 860kG
Output Voltage: 380 V
Efficiency: >91%
LCD Display: In/Out Voltage,Frequency,DC,Current,Temperature,Status,etc.
Certifications: CE/LTC/UKAS
MTBF: 300000hr
Warranty: 36 months
Show

Product Description

DSP Technology: The advanced DSP digital control technology enable UPS more stable performance.
Environment Friendly:This UPS is eco-designed and manufactured to meet the China localpollution control requirement of Electronic Products, which means itwill cause no harm to environment and human beings in normal usage.
Zero power switch delay: Whenthe utility power fails, UPS will automatically switch from AC mode tobattery mode with no delay, which will ensures stable power supply ofoperating system.
Sufficient Expansion Slots: Thepre-allocated smart slots enable flexibility in choice of USBcards,AS400 cards, CMC monitoring cards, SNMP cards, RS485 cards and EMDenvironment monitoring cards.
Support the Generators: Thewide range of input voltage and frequency can effectively separate theharmful electric wave produces by the generators and provide safe andreliable power supply.
RL-H/P technical parameters:
 
RLT80K-H~400K-H(3IN~3OUT)
Model
RLT100K-H
Capacity(KW)
100KVA/80
Input
Three-phase 4+GND,380 V±25%
Output
Three-phase 4+GND,380 V±1%
DC input
396V
DC range
347V~446V
Noise
≤60dB(1m)
Size(W*D*Hmm)
1200*800*2000+600*800*2000
Weight(KG)
950
Input
Frequency
50Hz/60Hz±10%
Output
Frequency
50Hz/60Hz±0.05%
Wave
Sine<3%(liner load),<5%(nonlinear load)
Imbalance voltage
≤1%(liner load), ≤3%(nonlinear load)
Phase angle
≤1°(liner load), ≤3°(nonlinear load)
Transition range
≤3%(0~50%100%Load),restore in 10ms
Overload
125%≥10Min,150%≥20s
Peak factor
5:1
Switch time
0ms
Efficiency
AC in to out
Up91%
Alarm
DC discharge
No input, beep once every 4s
DC low, beep once per second
DC halt, beep
System failure
Beep
Protect
DC low
Auto shutdown as DC low
Overload
Auto Bypass as load(110~150%) within30s
Heat
Inside>85°C, auto BYPASS
Output shock
Auto shutdown
UPS System fault
Automatic to BYPASS
Interface
LCD Display
In/Out voltage, freq, DC,
Property
MTBF
300000hr
Environment
T : -10°C~50°C, Hum:0-93°C, H: ≤3000m
Communication
Novell Netware Microsoft Windows9X/2000/XP/NT Linux
Case protect
Insulate transform between IN-OUT lightning protection