ETCO2+SPO2 Patient Monitor 3.5 Inch

Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer, Distributor/Wholesaler
Main Products: Diagnosis Equipment, Medical Product, Medical Cable, NIBP Cuff, IBP Cable

Product Detail

Model No.: RSD2001A

Product Description

RSD2001A is a Portable Patient Monitor that has abundant monitoring functions and is used for the clinical monitoring of adult, pediatric and neonate. In addition, the user may select the different parameter configuration according to different requirements.
 
RSD2001A (standard)can monitor vital signals correlating to SpO2 and CO2. It integrates parameter measuring modules and display in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. The LCD of high resolution and bright LED display provides clear view of 2 waveforms,SPO2,PR,EtCO2,InCO2,Respiration rate.
Specifications
Display
Messages:   
2 Waveforms
2 indicator lights
2 Sound Mode corresponding Alarm Mode
Device:
1 dot matrix LCD              size: 3.5",  resolution: 256X120
5 digital LED windows            
CO2
Method        Infra-red Absorption Technique
Measuring mode        Sidestream
Side-stream mode sampling gas flow rate
100, 150, 200 ml/Min (option)
Measuring range
CO2            0~99 mmHg
INSCO2      0-99 mmHg
AwRR         0~150 rpm
Resolution
CO2             1 mmHg
INSCO2       1mmHg
AwRR            1 rpm
Accuracy
CO2               
2 mmHg,0 ~ 40 mmHg
5% of  reading,41 ~ 76 mmHg
10% of  reading, 77 ~ 99 mmHg
AwRR     2 rpm
Actualization interval     about 1 Sec.
Start-up Time:   < 10 sec
Rise Time:  240 msec (10% to 90 %)
Delay Time:  1.12 seconds maximum with 7| length, 0.055|| ID.
Sampling line at 175 ml/min 
Alarm range  
CO2     0 ~ 99 mmHg
InsCO2    0 ~ 99 mmHg      
AwRR      0 ~ 150 rpm
Suffocation Alarm Delay
AwRR    10 ~ 40 Sec
SpO2
Measuring Range    0 ~ 100 %
Alarm Range    0 ~ 100 %
Resolution     1 %
Accuracy     70% ~ 100%  2 %
                      0%  ~  69% unspecified
Actualization interval     about 1Sec
Alarm Delay     10 Sec.
Pulse Rate
Measuring and Alarm Range    
0~254bpm
Resolution    1bpm
Accuracy    2bpm
Alarm Delay   10 Sec.
Recall
Trend Recall
8 to 96hours all parameters result.
NIBP Measurement Recall
50 NIBP measurement data.
Signal Interface
Amplitude   1 V/mV
Accuracy     < 5 %
Impedance   50
Signal Delay    < 20 mS
Battery      
Rechargeable 4.0 A/Hr 8.4V Li-ion battery
Operating time under the normal use and full charge greater than 4 hours
Operating time after the first alarm of low battery will be about 5 minutes
Maximum charging time is 4 hours
Environment
Temperature
Working    0 ~ 40 degrees
Transport and Storage   -20 ~ 60 degrees
Humidity
Working   30% - 85 %
Transport and Storage   30% - 93 %(no coagulate)
Altitude
Working   -500 to 4,600m
Transport and Storage    -500 to 13,100m
Power Supply
100/250 VAC, 50/60 Hz (for adapter)
Pmax=30VA
Dissipation
Working     Less than 3W
Power-off   Less than 0.1W                  
Size and Weight
Size      318 x 152 x 264  mm
Weight   5.5  kg
Accessories
Standard:
Model number: RSD 2001A SPO2+ETCO2
1 main unit
1 SPO2 cable
10 ETCO2 tube
1 user manual
Optional:
Model number: RSD 2001B SPO2+NIBP
Model number: RSD 2001C ETCO2
Model number: RSD 2001D SPO2
Model number: RSD 2001E SPO2+NIBP+ETCO2
Printer