Model:TYG60K |
Solar Panel |
Type | TYP-250W |
Rated Maximum Power | 250W |
Maximum Power Voltage (Vmp) | 30V |
Maximum Power Current (Imp) | 8.33 |
Open Circuit Voltage(Voc) | 35.7 |
Short Circuit Current(Isc) | 9.17 |
Power Toerance | ±3% |
Maximum System Voltage | 1000V |
Operating Temperature | -40℃~+85℃ |
Standard Test Conditions | AM1.5 100mW/cm2 25'C |
Size | 1640x990x40MM |
Weight | 16.5KG |
Quantity | 240PCS |
Inverter |
PV side | Grid side |
Max. PV power | 60KWp
| Rated output power | 60KW |
Max. permitted DC Voltage | 1000Vdc | Max.output current | 75.8A |
Input short-circuit current | 156A | THD of grid current | <3% |
Max. permitted DC current | 125A | Power factor | >0.99(adj. ±0.9) |
MPPT number | 2 | Max. Efficiency | 96.50% |
MPPT voltage range at full power | 420~820Vdc | European efficiency | 95.50% |
PV Start Voltage | 465Vdc | Output voltage | 320-450Vac 3 |
MPPT efficiency | 99.90% | Permitted grid frequency range | 47.5~51.5Hz |
|
| Nighttime power consumption | <30W |
Mechanical Data | Grid monitoring | According to VDE126-1-1 guidelines |
Dimensions (W × H × D) | 800×1780×800 mm
| communication interface | RS485/Ethernet/USB/GPRS(optional) |
Weight | 742kg | Man-machine interface | LCD |
Environmental conditions and safety |
Isolation | Transfomerless |
Protection level | IP65 |
Cooling | Air cooling |
Operating temperature range | -25~+60℃(above 45℃need derate operating ) |
Relative humidity range | 15-95% (non condensing) |
Noise emissions | <50dB |
Accessories | String Combiner Box/Solar brackets/Cables/User manual |