Ethylene Oxide Mixed Gas Sterilizer |
Type:XG2.SHE-0.6(Single Door) |
Made Department:Disinfection and sterilization equipment branch |
Overall Dimensions:1574×1240×1930mm |
Net Weight:1400kg |
|
|
|
USAGE |
|
Product Introduction
■EOS blending gas is used for sterilizing medium, this series of sterilizer is mainly used to sterilize products unable to stand for heat and moisture such as medical macromolecule material, medical sanitation material, some Chinese and Western medicine. It has functions of auto control on EO entry, time, temperature and residue gas disposal.
■Sterilizing with EOS has advantages such as broad-spectrum sterilization, high penetrability(also penetrate through cloth, paper box and polyethylene film ), no harm to materials being sterilized, easy storage for the materials being sterilized etc. |
|
|
Specifications |
|
Technical Parameter
Chamber Size: 1200×610×910mm
Chamber Volume: 0.6cubic meters
Packing Dimensions: 1800×1400×2400mm
Control Power: AC220V/50Hz 0.5 kw
Dynamic Power: 380V
Heater power: 15kw
Vacuum pump power: 2.35kw
Max Water Consumption: 200kg/cycle
The whole sterilization period: 6-10h |
|
|
Characteristics |
|
Configuration
■The inner shell and door board are made of 304 stainless steel and polished.
■Slopy pneumatic valve from GEMU, Germany.
■Germany burkert Steam entry electromagnetic valve.
■Germany nash_elmo Vaccum Pump.
■GRUNDFOS circulation pump from Danmark.
■Special control system
■The tiny printer records date and parameters in the course of sterilization |
|
|
|
|
■Mirror polishing with 304 stainless steel for inner contruction and door ■Burkert electro-magnetic valve from Germany ■nash_elmo vacuum pump of Germany ■GRUNDFOS cycle pump of Denmark ■Special control system ■Mini printer for recording
|
|
|
|
|
Standard on the product
■YZB/0116-2003 |
|
|
|
|
Installation requirements
■Steam Source Pressure:0.3~0.5Mpa
■Water Source Pressure:0.15~0.3Mpa
■Compressed Air Source Pressure:0.5~0.7Mpa |
|
|
|