user login

0.6M 1.2M 1.5M 1.8M Linear Tubular Emergency LED T8 Tube Light kit with external emergency kit Emergency T8 LED Lamp

Trade Term: FOB,EXW
Payment Terms: L/C, T/T, WU
Supply Ability: 10000sets per month
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company, Agent, Distributor/Wholesaler

Product Detail

Model No.: CNC-T8E-2835
Means of Transport: Express, Ocean, Air
Input Voltage: Others
Correlated Color Temperature: Others
Shape: Others
Light: Others
Material: Others
Lamp Holder/Base: Others
Lamp Holder: Others
Length and power: 10W/0.6M, 20W/1.2M, 25W/1.5M, 30W/1.8M
Driver: External isolated,Emergency
Duration Time: 3 hours
Charging Time: 3 hours
Emergency power: 3W
Input Voltage: AC 100-240V
LED Chips: SMD2835
Output Voltage: 30-39V
Output Voltage(Battery Charging): DC 4.7-8.4V
Warranty: 5 years
Production Capacity: 10000sets per month
Delivery Date: 10-20 working days
Show

Product Description

Product Name:0.6M 1.2M 1.5M 1.8M Linear Tubular Emergency LED T8 Tube Light kit with external emergency kit, Emergency T8 LED Lamp Kit

Model: CNC-T8E-2835

---Picture of  0.6M 1.2M 1.5M 1.8M Linear Tubular Emergency LED T8 Tube Light kit with external emergency battery kit

 

 

 

Features:

• Led type: Epistar SMD2835

• External isolated driver

• Duration Time: 3 hours

• Charging Time: 3 hours

 

 

Specification:

Power

Dimension

LED Qty

Lumen

3-10W

Φ28mm*L600mm

48pcs

285lm~950lm

3-20W

Φ28mm*L1200mm

96pcs

285lm~1900lm

3-25W

Φ28mm*L1500mm

120pcs

285lm~2375lm

3-30W

Φ28mm*L1800mm

144pcs

285lm~2850lm

Emergency: 3W

Emergency: 285lm

Color Temperature: 3000K/4000K/6000K

CRI: 72Ra

Power Factor: 0.95

Input Voltage: AC 100-240V

View Angle: 145°  

Working Temperature: -20℃-45℃

Output Voltage: 30-39V

Output Current: 70mA

Input Power: 3.5W/Max

Output Voltage(Battery Charging): DC 4.7-8.4V

Charging Current: 275mA

Power Efficacy: 70%

----wiring diagram of 0.6M 1.2M 1.5M 1.8M Linear Tubular Emergency LED T8 Tube Light kit with external emergency battery kit  

 

 

Dimensions:

Product

LED tube 600mm

LED tube 1200mm

LED tube 1500mm

LED tube 1800mm

Emergency Driver

Diameter

28mm

28mm

28mm

28mm

40mm

Length

588mm

1198mm

1498mm

1763mm

222mm

 

---Product size of 0.6M 1.2M 1.5M 1.8M Linear Tubular Emergency LED T8 Tube Light kit with external emergency battery kit

 

 

Electrical Parameter:

LED Tube

State

Power

Input

Voltage

Power

Efficiency

Power

Factor

THD

PFC

Output

Accuracy

600mm

City Electricity

10W

AC100~240V

86%

0.97

< 14%

PFC

< 3%

Emergency

3W

80%

< 5%

1200mm

City Electricity

20W

AC100~240V

86%

0.97

< 14%

PFC

< 3%

Emergency

3W

80%

< 5%

1500mm

City Electricity

25W

AC100~240V

86%

0.97

< 14%

PFC

< 3%

Emergency

3W

80%

< 5%

1800mm

City Electricity

30W

AC100~240V

86%

0.97

< 14%

PFC

< 3%

Emergency

3W

80%

< 5%

 

Optical Parameters:

LED Tube

State

Luminous flux

Efficiency

Illuminance

600mm

City Electricity

880lm

88lm/W

1m

2m

3m

Emergency

250lm

83lm/W

201lux

47lux

21lux

1200mm

City Electricity

1800lm

90lm/W

39lux

12lux

6lux

Emergency

250lm

83lm/W

312lux

87lux

42lux

1500mm

City Electricity

2250lm

90lm/W

30lux

8lux

4lux

Emergency

250lm

83lm/W

361lux

113lux

54lux

1800mm

City Electricity

2850lm

95lm/W

27lux

6lux

2lux

Emergency

250lm

83lm/W

416lux

137lux

66lux

(All the figures are tested by the tube of daylight (6000K)

 

 

Product Features:

Emergency LED T8 tube lights are designed for unexpected situation, which can maintain lighting with battery when the city electricity is off suddenly. 

Also, they can work as normal lighting source and supply enough light in daily work and life. 

1. Super bright LED tube with emergency function; 

2. Input voltage: AC 100-240V; 

3. Duration time: 3 hours; 

4. Emergency mode power: 3W; 

5. Operating temperature: -20℃~45℃; 

6. IP42 protection rating; 

7.  ≥36000 hours life span; 

8. 2 years warranty.

 

 

Emergency Driver:

---Picture of  external emergency battery kit for 0.6M 1.2M 1.5M 1.8M Linear Tubular Emergency LED T8 Tube Light kit

---size of external emergency battery kit for 0.6M 1.2M 1.5M 1.8M Linear Tubular Emergency LED T8 Tube Light kit

 

 

 

Except for normal lighting, emergency LED T8 tube light has a rechargeable lithium battery in the external driver, which is used for emergency lighting. For showing operating state, there are three indicators on it.   

Red indicator:

On-----charging 

Off----- charged 

Yellow indicator: 

On-----System failure 

Off-----Working 

Green indicator: 

On-----electricity supply 

Off-----electricity disconnected 

 

Indicating Wire: 

In order to inform the working state of emergency driver more conveniently, indicating wire is available, which is inserted on the end of driver. The switch is used for emergency function test, and the purpose of red, yellow and green indicators is the same as the three indicators on the driver.

 

 

---sizes and explains for emergency indicator wires of 0.6M 1.2M 1.5M 1.8M Linear Tubular Emergency LED T8 Tube Light kit with external emergency battery kit  

 

 

 

Function:

The emergency LED T8 tube light can switch automatically between normal lighting and emergency lighting. If there is no city electricity, the battery will be in operation. Two modes are available:   

City electricity mode: When the city electricity is connected, the LED tube can work as normal lighting for daily life. The battery in external emergency driver is being charged automatically. 

Emergency mode: If the city electricity fails, the battery will work and supply power to the LED tube for lighting. And the emergency lighting can last for 3 hours. Perfect protection is applied for the battery when voltage is low and short circuit happens.

 

 

Installation:

 

· Switch off the power of mains supply and respectively of the connection lead before installation to avoid electrical shock; 

 

· Emergency LED tube is fixed in the light fixture same as the normal LED tube; 

 

· Use screw to fasten the emergency driver on flat place; 

 

· Switch wire is connected to L, and AC 100-240V city electricity supply power to L and N; 

 

· The product is used indoor only and kept away from direct sunshine and high temperature.

 

---installation for 0.6M 1.2M 1.5M 1.8M Linear Tubular Emergency LED T8 Tube Light kit with external emergency battery kit  

 

Test

---Illuminance in city electricity state of Daylight(6000K) 1200mm  Linear Tubular Emergency LED T8 Tube Light kit with external emergency battery kit  

---Illuminance in emergency state of Daylight(6000K)  Linear Tubular Emergency LED T8 Tube Light kit with external emergency battery kit  

 

Packaging & Shipping

 Packing:

Length

Outer Carton size

(L*W*H)

Qty/Carton

N.W.

G.W.

600mm LED tube

645x265x218mm

20pcs

6.50kg

7.00kg

1200mm LED tube

1260x265x218mm

20pcs

11.30kg

12.60kg

1500mm LED tube

1570x265x218mm

20pcs

15.20kg

16.00kg

1800mm LED tube

1830x265x218mm

20pcs

19.2kg

20.4kg

Emergency driver

580x260x210mm

40pcs

13.6kg

15.00kg

 


Post Buying Request