Patient Monitor CE Approved

Payment Terms: Paypal, T/T, WU
Place of Origin: Hebei

Company Profile

Location: Qinhuangdao, Hebei, China (Mainland)
Business Type: Manufacturer, Trading Company, Distributor/Wholesaler
Main Products: Medical Equipment, Pocket Fetal Doppler, Wrist Pulse Oximeter, Fetal Doppler, Medical Doppler

Product Detail

Model No.: CMS7000
Packing: carton
Delivery Date: in five days after receipt of payment

Product Description

Multi-parameter patient monitor is the one of high price/ performance ratio, high security and low consumption of power. In order to insure the quality and reduce the risk may occur in the operation process, it adopts the technology of full isolation floating, ECG anti-defibrillation protection, ECG Anti-high-frequency interference, and NIBP Dual Over Pressure protection to prevent the damage caused by single problem. It makes this product safe and efficient.

Feature
| 12.1"High bright TFT LCD display
| Portable, streamline handle design
| Big figure display  
| ECG Waveforms of 7-lead displayed in one screen
| 96-hour tabular and graphic trends & date storage
| Compatible and self identify 3-lead and 5-lead ECG cable
| NIBP dual Over Pressure Protection
| Isolated floating, anti defibrillation protected and anti high-frequency interference
| Networking capacity
NIBP:
| Method: Oscillometry
| Modes: Manual/Auto/Continuous
| Auto measure time: Adjustable
| Measurement rang: 10-270mmHg
ECG:
| Lead mode: 3-lead or 5-lead
| Lead selection: I, II, III, avR, avL, avF, V
| Heart rate range: Adult: 15-300bpm,   Pediatric/Neonatal: 15-300bpm
| ECG waveform: 2 channels
| Accuracy: ± 1 bpm or ±1%
| S-T segment detection Measurement range:-0.2mv~2.0mv
| Alarm: Yes, audible and visual alarm, alarm events review
SPO2
| Measurement range: 0-100%
| Accuracy: 70-100%, ±2% 0-69%,upspecified
Pulse rate
| Range: 20-254bpm
| Accuracy: ±3bpm
Respiration
| Method: RA-LL impedance
| Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm
| Apnca alarm: Yes
Temperature
Range: 0-50℃
| Apnca: 0.1℃
| Channel: Dual-Channel
Standard parameter & configuration
| 3/5 lead ECG, RESP, SpO2, NIMP, TEMP, PR, Network
Optional parameter & configuration
| 2-IBP, Recorder,12 lead ECG, ETCO2

Option:
EtCO2

Measurement Mode: Side-stream or mainstream
Measurement range: EtCO2: 0-99mmHg
Accuracy: CO2 concentration
Apnea alarm: YES

IBP

Channel: 2 channels
Pressure transducer: Sensitivity: 5( mV/V/mmHg)
Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Alarm range: -10~300mmHg

Printer