Wrist Pulse Oximeter CE FDA

Payment Terms: Paypal, T/T, WU
Place of Origin: Hebei

Company Profile

Location: Qinhuangdao, Hebei, China (Mainland)
Business Type: Manufacturer, Trading Company, Distributor/Wholesaler
Main Products: Medical Equipment, Pocket Fetal Doppler, Wrist Pulse Oximeter, Fetal Doppler, Medical Doppler

Product Detail

Model No.: CMS50I
Packing: CARTON
Delivery Date: DELIVERY IN FIVE DAYS

Product Description

Wrist Pulse Oximeter, Blood Oxygen Monitor, SPO2,PC software, CMS50I CE FDA

Wrist Pulse Oximeter CE FDA

Major Features

Small in volume\light in weight and convenient in carrying
Operation of the product is simple ,low power consumption
Operation menu for the function setting
SpO2 value display
Pulse rate value display, bar graph display
Pulse waveform display
With PI display
The display mode can be changed
Screen brightness can be changed
A pulse rate sound indication
Multi-time segment storage
With measured data overruns limits and low-voltage alarm function,the upper/down alarm range is adjustable
Battery capacity indication
Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage ,and with alarm function
With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers
Real-time data can be transmitted to computers
Connected with an external oximeter probe
Power-off: long press power button to turn off the device
Wireless communication function(CMS50IW)

Main performance

Display Mode: 1.5" Color OLED display
Screen Resolution: 128*128
SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
Accuracy: 70%~100%: ±2% ,Below 70% unspecified.
PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
Accuracy: ±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:  
SpO2 and pulse rate can be shown correctly when pulse-filling ratio
is 0.4%,SpO2
error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light:   The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption: less than 100mA
Voltage: DC 3.6V~4.2V
Power Supply: Voltage 3.7 rechargeable lithium battery × 1  
Battery working hour: 10 hours
Battery working life: Charge and discharge no less than 500 times.
Safety Type: Interior Battery,BF Type

Accessories

Sell in standard:  
A user manual
A data line
A disk (PC software)
An adult-oximeter probe
Two One-off adhesive SpO2 probe
A power adapter (GTM41076-0605;CMS0105)

Sell in addition:  
Other oximeter probe(Refer to probe application instruction for details and notice renewal)

Physical Identity
Dimension: 63(L) × 55(W) ×15(H) mm
Weight: About 45g (with the lithium battery*1)